Homepage UV-VIS Spectrophotometers

Spectrophotometer Cells

 

Technical Details and Illustrations below

go to the Price List
 

Spectronic cells and cuvettes meet the most exacting requirements of modern spectrophotometric procedures. All spectrophotometer cells are completely fused without the use of low melting intermediate glasses or cements. In other words, quartz is fused to quartz and glass is fused to glass. This eliminates strains due to differences in coefficients of expansion found in cells fused with intermediate low melting temperature glasses. Because of the fused construction, the window joints of Spectronic spectrophotometer cells are unaffected by all types of cleaning solutions.

General specifications

Windows parallel to:
Window flatness to:
Window polish, standard:
Window polish, laser:

better than 3 minutes of arc
better than 4 Newton fringes
60/40 scratch/dig
20/10 scratch/dig
 
Material
Path lengths
Tolerance

Glass
Glass
Glass
Special Optical Glass
Special Optical Glass
Quartz
Quartz
Quartz

less than 10mm
10 to 30mm
40 to 100mm
up to 20mm
30 to 100mm
0.01 to 0.05mm
0.1 to 0.4mm
0.5 to 100mm
± 0.02mm
± 0.1mm
± 0.2mm
± 0.01mm
± 0.02mm
± 0.002mm
± 0.005mm
± 0.01mm

Standard window thickness is 1.25mm, polished to better than 4 Newton Fringes per centimetre in the viewing area, typically flat to better than 1 micron (0.001mm) over the window area.
Although cells can be used with most solvents and acidic solutions, fluorinated acids such as Hydrofluoric Acid (HF) in all concentrations should be avoided as they will attack the quartz itself. Strong basic solutions (pH 9.0 and above) will also degrade the surface of the windows and
shorten the useful life of the cells.
Flow cells with path lengths of less than 0.5mm are measured by an interference method both before and after final fusing.Calculation on this measurement provides an uncertainty of path length better than 0.2 microns (0.0002mm). Path length certification can be supplied for individual cells for a small additional charge.This must be requested at the time of ordering.

Window material transmission properties
 
Registered Trade Marks: INFRASIL® & Suprasil® 300 Heraeus Quarzglas GmbH, Hanau / Main, Germany.
SPECTROSIL®, Thermal Syndicate, England. PYREX® Corning Glass Works, U.S.A.
The above information illustrates the approximate transmission ranges of the guaranteed materials used in the production of Starna cells. The traces are for a thickness of 5 mm, which is approximately double the total thickness of the windows that are used in the construction of most cells.
Material specifications
Optiglass offer five primary window materials, Optical Glass (G) and Special Optical Glass (SOG) for the visible range. Spectrosil® Quartz (Q) or equivalent for the far UV range, Infrasil® Quartz (I) or equivalent for the near infra-red (IR) as well as Suprasil® 300 (SX) or equivalent which transmits from the far UV to the near infra-red. Other window materials are also available such as Pyrex (PX) and UV Silica (HH).
If a specific window material is required and is not shown in this catalogue please contact us for availability. All materials used are fully guaranteed to transmit greater than 80% over the following usable wavelength range:
Optical Glass
Special Optical Glass
Pyrex
UV Silica
Spectrosil® Quartz
Infrasil®
Suprasil® 300 Quartz
G
SOG
PX
HH
Q
I
SX
334 through 2500 nm
320 through 2500 nm
325 through 2500 nm
230 through 2500 nm
190 through 2700 nm
220 through 3800 nm
190 through 3500 nm
For fluorescent applications Spectrosil® is the recommended window material, as it does not exhibit any background fluorescence. Some other materials, especially glass and lower grades of quartz may have some background fluorescence.
The meticulous care taken in the quality of the polishing and unique construction of regular Starna® quartz fluorescent cells brings them within tolerances which are sufficiently stringent for them to be used in laser applications. These techniques are particularly relevant in the manufacture of much larger Ultra High Vacuum (UHV) cells.

 

Spectrophotometer Cells the following are standard cuvettes we supply on a regular basis, if you require any other special cells. Please contact sales@spectronic.co.uk

 

Type 1 Standard Spectrophotometer CuvetteType 1 Standard Spectrocell
Type 3 Standard Fluorimeter cuvetteType 3 Standard Fluorocell
Type 9 Semi Micro cellType 9 Semi Mic Spectrocell

Cell with fitted cover.Satin finish on 2 sides. Vol. of 10mm P.L. cell is 3.5ml
Lightpaths: 1, 2, 5, 10, 20,40, 50 and 100 mm.
Outside dimensions:45 mm high, 12.5 mm wide.

Manufactured in

Glass,Quartz,or Infrasil

Cell with fitted cover Polished on 4 sides & bottom. Vol. of 10mm P.L. cell is 3.5ml
Lightpaths: 2, 5, 10, 20, 40, 50,and 100mm
Outside dimensions:45 mm high, 12.5 mm wide.

Manufactured in

Glass or Quartz

Semi-micro cell with fitted cover.
Satin finish on two sides.
Inside width 4mm. Vol. of 10mm P.L. cell is 1.4ml
Lightpaths: 5, 10, 20 and 40 mm.
Outside Dimensions: 45 mm high x 12.5 mm wide.

Manufactured in

Glass,Quartz,or Infrasil

 

 

Type 1 Standard Spectrophotometer CuvetteType 9 BM SemiMic Spectrocell
Type 3 Standard Fluorimeter cuvetteType 17 Micro Spectrocell
Eutech CyberscanpH510 Laboratory pH MeterType 17 BM Micro Spectrocell

Semi micro spectrophotometer Cell masked in Black Quartz with fitted cover.Inside width 4mm. Vol. of 10mm P.L. cell is 1.4ml
Lightpaths: 5, 10, 20, and 40
Outside dimensions :45 mm high, 12.5 mm wide.

Manufactured in

Quartz only

Micro Cell with fitted cover Polished on two sides half height
Inside width 2 mm Lightpaths: 5,10, 20, 40 mm Vol. of 10mm P.L. cell is 0.4ml
Outside dimensions:25 mm high, 12.5 mm wide.

Manufactured in

Glass or Quartz

Semi-micro cell with fitted cover.
Polished on two sides. Inside width 2 mm.
Lightpaths: 5, 10, 20 and 40 mm. Vol. of 10mm P.L. cell is 0.4ml
Outside Dimensions:25 mm high x 12.5 mm wide.

Manufactured in

Glass or Quartz

 

 

Type 1 Standard Spectrophotometer CuvetteType 18 BM Micro Spectrocell
Type 3 Standard Fluorimeter cuvetteType 21 Standard Spectrocell
Eutech CyberscanpH510 Laboratory pH MeterType 75 BM flowcell Spectrocell

Semi micro spectrophotometer Cell masked in Black Quartz with fitted cover.Inside width 4mm Vol. of 10mm P.L. cell is 0.7ml
Lightpaths: 5, 10, 20, and 40
Outside dimensions :45 mm high, 12.5 mm wide.

Manufactured in

Quartz

Same as Type 1, but with
tapered PTFE stopper.

 

 

Manufactured in

Glass , Quartz or Infrasil

Continuous flow-through ultra-micro. Two windows polished. Internal width of sample chamber: 3 mm diameter.
Lightpath: 10mm only.
Outside Dimensions:
45mm high x 12.5mm wide.

Manufactured in

Quartz

 

 

 

go to the Price List

Return to Top of Page

Return to HomePage