Homepage Analytical Instruments

JENWAY 62series FLUORIMETER

Jenway 6200 Fluorimeter

Three models are available to cover a wide range of applications. Choose the Model 6280 for the most sensitive determinations with emission wavelengths up to 650nm. Where higher emission wavelengths will be experienced choose the Model 6285 with its red-enhanced detector. For less sensitive applications with a broader range choose the low cost Model 6270.

All three models offer intuitive operation with a user interface based on logical menus that can be navigated from the simple keypad. Up to 20 methods can be created without restriction and be saved for future use. They can also be locked against accidental change by password entry, ensuring data integrity.

Total Energy Transfer (TET) system for maximum sensitivity

Create and Save secure methods Intelligent Filter Modules (IFM) ensure correct filters are fitted

Raw fluorescence and Concentration values displayed

Calibration against up to 6 standards possible

Kinetic (timed reading) functions

Electrically heated sample holder and sipper pump options

Compatible with DataWay PC software

 

SPECIFICATIONS

Light Source

Pulsed Xenon Lamp with press-to-read operation

Expected Lifetime

No replacement required in normal operation

Detector

Photomultiplier (Models 6280 & 6285)
Photodiode (Model 6270)

Sensitivity (Quinine Sulphate)

<1ng/ml (Models 6280 & 6285)
1µg/ml (Model 6270)

Dynamic Range

5.2x106 (Models 6280 & 6285)
5.2x104(Model 6270)

Wavelength Range

190 to 650nm (Model 6280)
190 to 850nm (Model 6285)
190 to 1100nm (Model 6270)

Wavelength Selection

Intelligent Filter modules (IFM)

Raw Fluorescence

available on all models

Concentration

available on all models

Calibration

Blank + up to 6 standards on all models

ACCESSORIES

620 124 BG28 bandpass filter 380-500nm
620 125 VG9 bandpass filter 480-580nm
 
620 126 UG1 bandpass filter 320-380nm
 
620 127 Kodak 29 cut-off filter 610nm
 
620 128 Ilford 201 cut-off filter 545nm
 
620 129 Kodak 8 cut-off filter 475nm
 
620 130 Kodak 2B cut-off filter 395nm
 
620 131 Glass cut-off filter 305nm
 
620 141 Interference filter 250nm
 
620 132 Interference filter 254nm
 
620 142 Interference filter 260nm
 
620 143 Interference filter 265nm
 
620 144 Interference filter 270nm
 
620 145 Interference filter 280nm
 
620 146 Interference filter 290nm
 
620 147 Interference filter 295nm
 
620 148 Interference filter 300nm
 
620 149 Interference filter 305nm
 
620 150 Interference filter 310nm
 
620 151 Interference filter 313nm
 
620 152 Interference filter 320nm
 

ORDER CODES

627 001

Model 6270 Fluorimeter (190-1100nm) supplied with 100 disposable cuvettes (060 247), universal power supply with UK, European & US leads (021 056) and operating manual.

628 001

Model 6280 Fluorimeter (190-650nm) supplied with 100 disposable cuvettes (060 247), universal power supply with UK, European & US leads (021 056) and operating manual.

628 501

Model 6285 Fluorimeter (190-850nm) supplied with 100 disposable cuvettes (060 247), universal power supply with UK, European & US leads (021 056) and operating manual.

Return to Top of Page