Homepage Analytical Instruments

Jenway Ion Meter Accessories

A number of accessories for use with the Jenway Ion Meter range are detailed below.

pH and CONDUCTIVITY ELECTRODES

The pH and Conductivity electrodes listed below are for use with Models 3510 and 3520 Laboratory pH Meters, 4510 and 4520 Laboratory Conductivity Meters and the 3345 Laboratory Research pH/Ion Analyser. All electrodes should be used at atmospheric pressure only. All electrodes (except *) are combination type with integral reference, operate over the range of 0-14pH, have an overall length of 120mm and are fitted with a 1 metre cable as standard. Alternative cable lengths are available on request.

Order Number
Electrode Description
Temperature Range
Diameter
Application
924 001
General purpose, epoxy bodied
0 - 60ºC
12mm
Liquids
924 002
Spear type, 12mm stem, glass bodied
0 - 80ºC
12mm
Slurries
924 003
Redox - platinum, glass bodied
0 - 80ºC
12mm
Liquids
924 004
Micro 40mm stem, glass bodied
0 - 80ºC
4.5mm (Stem)
Liquids
924 005
General purpose, glass bodied
0 - 80ºC
12mm
Liquids
924 006
Flat head, glass bodied
0 - 80ºC
12mm
Surfaces
924 007
Semi-micro, 90mm stem, glass bodied
0 - 80ºC
4.5mm (Stem)
Liquids
924 008
Long reach micro, 150mm stem, glass bodied
0 - 80ºC
7.5mm (Stem)
Liquids
924 010
Spear type, 40mm stem, glass bodied
0 - 80ºC
6mm (Stem)
Semi-solids
924 011
Spear type, 25mm stem, glass bodied
0 - 80ºC
4mm (Stem)
Semi-solids
924 029
Low Conductivity Waters, glass bodied
0 - 50ºC
12mm
Liquids
924 030
Tris buffer, 90mm stem, glass bodied
0 - 50ºC
6mm (Stem)
Biological fluids
924 047
3 in 1 electrode, epoxy bodied (integral temp.)
0 - 80ºC
12mm
Liquids
924 015
pH electrode, glass bodied *
0 - 80ºC
12mm
Liquids
924 016
Calomel reference, SJ, glass bodied
0 - 50ºC
12mm
Liquids
924 017
Ag/AgCl reference, DJ, glass bodied
0 - 50ºC
12mm
Liquids
924 036
Ag/AgCl reference
0 - 100ºC
12mm
Liquids

ION SELECTIVE ELECTRODE KITS - ORDER CODES

924 402 Ammonium Electrode Kit comprising Ammonium ISE, instruction manual,
1 bottle of calibrating standard (1000ppm), 1 bottle of ISAB and BNC to S7 adaptor lead.
924 401 Calcium Electrode Kit comprising Calcium ISE, instruction manual,
1 bottle of calibrating standard (1000ppm), 1 bottle of ISAB and BNC to S7 adaptor lead.
924 404 Chloride Electrode Kit comprising Chloride ISE, instruction manual,
1 bottle of calibrating standard (1000ppm), 1 bottle of ISAB and BNC to S7 adaptor lead.
924 405 Fluoride Electrode Kit comprising Fluoride ISE, instruction manual,
1 bottle of calibrating standard (1000ppm), 1 bottle of ISAB and BNC to S7 adaptor lead.
924 400 Nitrate Electrode Kit comprising Nitrate ISE, instruction manual,
1 bottle of calibrating standard (1000ppm), 1 bottle of ISAB and BNC to S7 adaptor lead.

TEST SOLUTIONS - ORDER CODES

025 113 pH4 Buffer (100ml) capsule 10 off
025 114 pH7 Buffer (100ml) capsule 10 off
025 115 pH9 Buffer (100ml) capsule 10 off
025 116 pH10 Buffer (100ml) capsule 10 off
025 037 pH4 Buffer (500ml) red
025 038 pH7 Buffer (500ml) yellow
025 039 pH10 Buffer (500ml) blue
025 162 pH9.22 Buffer (500ml)
025 163 pH2 Buffer (500ml)
025 160 3M KCl electrode fill solution
025 161 Electrode cleaning solution
025 157 Redox standard (200mV) (500ml)
025 158 Redox standard (300mV) (500ml)
025 159 Redox standard (465mV) (500ml)

POWER SUPPLIES - ORDER CODES

These are for use with Model 3345 only.

021 030 UK 230V power supply
021 031 European 230V power supply
021 032 US 115V power supply
021 033 230V leaded power supply

MISCELLANEOUS - ORDER CODES

542 009 Interface cable kit
543 001 40 Column printer
903 200 Swing Arm Electrode holder

Return to Top of Page