Jenway offer a wide range of Conductivity Meters available as either portable or laboratory instruments. A brief summary of the Conductivity Meters available is outlined below, and further details can be found by following the link to the instruments individual page.
The Model 430 pH, Conductivity/TDS and temperature Meter provides a portable means of determining the pH, conductivity or TDS of a wide range of industrial or environmental samples. The instrument features an innovative new combined pH and conductivity probe assembly with an integral ATC sensor.
The Model 470 Conductivity/TDS Meter provides a portable means of determining the conductivity or TDS of a wide range of industrial or environmental samples. One of six measurement ranges (3 x conductivity, 3 x TDS) can be selected to get the best resolution of the sample under test. All results are automatically temperature compensated.
The Model 4200 Premier Portable Conductivity Meter measures between 0 and 199.9mS, covered by five automatically switched ranges using a single cell. In-built consumables is able to calculate and report results as Total Dissolved Solids in mg/l, Salinity in g/l or Resistivity in MOhms. A "pure water" mode enacts the non-linear temperature coefficient characteristics associated with low conductivity water.
The new Model 4510 Laboratory Conductivity Meter is designed for routine analytical laboratory situations. Simultaneous display of conductivity/TDS and temperature are available on the custom liquid crystal display. Calibration and result verification is possible by reference to standard calibration values.
The new Model 4520 Laboratory Conductivity Meter features a back-lit 1/8 VGA monochrome liquid crystal display. On-line "HELP" menus provide assistance when using this model. Conductivity values can be displayed in a selection of units suitable for the particular sample under test; Siemens for routine requirements, MOhms for samples with low conductivity (such as purified water) and Total Dissolved Solids relating conductivity to the concentration of NaCl. A salinity mode displays conductivity results in ppm NaCl. The meter supports 1, 2 or 3 point conductivity calibration.
The new GLP compliant Model 3540, a combined pH / Conductivity Meter is also available. The Model 3540 features simultaneous measurement of both pH and Conductivity with no electrical interference between sensors.
Below is a brief summary of the key specification differences between the Conductivity Meters available. Full specification details can be found by following the link to the instruments individual page.
| Model | 430 | 470 | 4150 | 4200 | 4510 ![]() |
4520 ![]() |
| Style | Portable | Portable | Portable | Portable | Laboratory | Laboratory |
| Display | Back-lit LCD |
Back-lit LCD |
Custom Segment LCD | 114 x 128 graphics LCD | Custom back-lit LCD | Back-lit 1/8 VGA monochrome LCD |
| Conductivity | ||||||
| Ranges | 0 - 19.99µS 0 - 199.9µS 0 - 1999µS 0 - 19.99mS 0 - 199.9mS |
0 - 19.99µS 0 - 199.9µS 0 - 1999µS 0 - 19.99mS 0 - 199.9mS 0 - 1999mS |
5 switched ranges 0 - 199.9mS |
5 switched ranges 0 - 199.9mS |
0 to 19.99µS 0 to 199.9µS 0 to 1999µS 0 to 19.99mS 0 to 199.9mS 0 to 1999mS |
0 to 19.99µS 0 to 199.9µS 0 to 1999µS 0 to 19.99mS 0 to 199.9mS 0 to 1999mS 0 to 19.99S |
| Resolution | 0.01µS 0.1µS 1µS 0.01mS 0.1mS |
0.01µS 0.1µS 1µS 0.01mS 0.1mS 1mS* * only with cell constant >5 |
0.1mS 0.01mS 1µS 0.1µS 0.01µS |
0.1mS 0.01mS 0.001mS 0.1µS 0.01µS |
0.01µS 0.1µS 1µS 0.01mS 0.1mS 1mS |
0.01µS 0.1µS 1µS 0.01mS 0.1mS 1mS 0.01S |
| Accuracy | ±0.5% ±2 digits | ±0.5% ±2 digits | ±0.5% ±2digits | ±0.5% ±2digits | ±0.5% ±2digits | ±0.5% ±2digits |
| Salinity | ||||||
| Range | 0 - 19.99mg/l 0 - 199.9mg/l 0 - 1999mg/l 0 - 19.99g/l 0 - 199.9g/l |
0 - 19.99mg/l 0 - 199.9mg/l 0 - 1999mg/l 0 - 19.99g/l 0 - 199.9g/l 0 - 1999g/l |
|
0 - 99.9g/l | 0 - 19.99mg/l 0 - 199.9mg/l 0 - 1999mg/l 0 - 19.99g/l 0 - 199.9g/l 0 - 1999g/l |
0 - 19.99mg/l 0 - 199.9mg/l 0 - 1999mg/l 0 - 19.99g/l 0 - 199.9g/l 0 - 1999g/l |
| Resolution | 0.01mg/l 0.1mg/l 1mg/l 0.01g/l 0.1g/l |
0.01mg/l 0.1mg/l 1mg/l 0.01g/l 0.1g/l 1g/l* * only with cell constant >5 |
|
0.1g/l | 0.01mg/l 0.1mg/l 1mg/l 0.01g/l 0.1g/l 1g/l* * only with cell constant >5 |
0.01mg/l 0.1mg/l 1mg/l 0.01g/l 0.1g/l 1g/l* * only with cell constant >5 |
| Accuracy |
|
|
|
0 to 35 ±1 35 to 99.9 ±3 of reading |
|
|
| Power | 2 AA Cells | 2 AA Cells | 3 AA Cells | 3 AA Cells | 9V AC PSU | 9V AC PSU |
| Internal Clock |
|
|
|
Yes |
|
Yes |
| Datalogging |
|
|
|
100 results | 32 results | 512 results |
| Dimensions | 175 x 75 x 35mm | 175 x 75 x 35mm | 200 x 80 x 60mm | 200 x 80 x 60mm | 250 x 210 x 50mm | 250 x 210 x 50mm |
| Weight | 250g | 250g | 370g | 370g | 850g | 850g |
An electro-chemistry theory and measurement guide is now available in PDF format
To view a PDF file you will need the Adobe Acrobat Reader.
If you do not have this installed on your computer, please use the free download service.