Rudolph Polarimeter Cells eliminate these problems by using stainless steel ends with built-in apertures which may be removed to allow the glass to be cleaned if necessary. Cells are manufactured using Pyrex glass and stainless steel for their high resistance to solvents, low temperature coefficient of expansion and general dimensional stability. |
| Easy Cleaning
|
|
Easy Filling Sample solutions are either poured or pipetted into the center well, side well or side tubulation. Air bubbles are released by tilting cells side to side or to one side while filling. Flexible tipped pipettes capable of reaching from the center well to either end of the sample can be helpful in filling narrow bore cells. |
|
AUTOPOLs Accept Sample Cells from 10mm to 200mm Long Some polarimeters accept only special sample cells, with maximum lengths of 100mm. AUTOPOL Polarimeters and saccharimeters accept cells up to 200mm long. A 200mm sample cell offers twice the sensitivity as the same solution in a 100mm cell. This additional optical path length is especially useful for solutions having small rotations. For precious samples and essential oils with large optical rotations, cells with only 0.02ml volumes and 10mm optical path lengths are available. |
|
Rapid Operation
|
|
Continuous Sampling Capability
|
|
|
|
|
|
Micro Volumes
|
|
With over forty-five cells to choose from, Rudolph Research Analytical has a cell to meet every application. Please call our offices for assistance in selecting the best polarimeter sample cell for your application. |
| Type | Description | Catalog Number |
ID (mm) |
Sample Length (±0.002mm) |
Sample Volume |
|
Type2 Polarimeter Sample Cells: Straight Pyrex glass cells with metal collars and screw ends. | 2-1.6-10-.02 | 1.6 | 10 | .02 |
| 2-4.0-10-.13 | 4.0 | 10 | .13 | ||
| 2-1.6-50-0.1 | 1.6 | 50 | 0.1 | ||
| 2-1.6-100-0.2 | 1.6 | 100 | 0.2 | ||
| 2-4.0-100-1.3 | 4.0 | 100 | 1.3 | ||
| 2-8.5-100-5.7 | 8.5 | 100 | 5.7 | ||
| 2-4.0-200-2.5 | 4.0 | 200 | 2.5 | ||
| 2-8.5-200-12 | 8.5 | 200 | 12 | ||
|
Type 6 Polarimeter Sample Cells: Pyrex glass with one enlarged end to trap air bubbles above the optical path. | 6-8.5-100-10 | 8.5 | 100 | 10 |
| 6-8.5-200-15 | 8.5 | 200 | 15 | ||
| Type 14 Polarimeter Sample Cells: Pyrex glass with center well for easy filling via pour-in method or with a flexible tipped pipette. | 14-4.0-100-1.5 | 4.0 | 100 | 1.5 | |
| 14-8.5-100-6.0 | 8.5 | 100 | 6.0 | ||
| 14-4.0-200-2.8 | 4.0 | 200 | 2.8 | ||
| 14-8.5-200-12 | 8.5 | 200 | 12 | ||
| Type 14J Jacketed Polarimeter Sample Cells: Pyrex glass with center well. The main body of the cell is completely surrounded by a stainless steel jacket with tubulations at each end for circulation of temperature control fluids. | 14J-4.0-100-1.5 | 4.0 | 100 | 1.5 | |
| 14J-8.5-100-6.0 | 8.5 | 100 | 6.0 | ||
| 14J-4.0-200-2.8 | 4.0 | 200 | 2.8 | ||
| 14J-8.5-200-12 | 8.5 | 200 | 12 | ||
|
Type 29 Flow-Through Sample Cells: Stainless steel with tubulations at each end for circulation of sample liquids. Designed so that sample flow washes interior windows eliminating dead volume in the optical path. | 29-8.5-100-10 | 8.5 | 100 | 10 |
| 29-8.5-200-15 | 8.5 | 200 | 15 | ||
|
Type 29J Flow-Through Jacketed Sample Cells: Type 29 but with a stainless steel jacket surrounding the main body of the cell for circulation of temperature control fluids | 29J-8.5-100-10 | 8.5 | 100 | 10 |
| 29J-8.5-200-15 | 8.5 | 200 | 15 | ||
|
Type 30 Polarimeter Sample Cells: Stainless steel with a well at either end for easy filling. | 30-8.5-50-5.0 | 8.5 | 50 | 5.0 |
| 30-4.0-100-3.7 | 4.0 | 100 | 3.7 | ||
| 30-8.5-100-10 | 8.5 | 100 | 10 | ||
| 30-4.0-200-5.0 | 4.0 | 200 | 5.0 | ||
| 30-8.5-200-15 | 8.5 | 200 | 15 | ||
|
Type 30J Jacketed Sample Cells: Type 30 with stainless steel jacket surrounding the main body of the cell for circulation of temperature control fluids. | 30J-4.0-100-3.7 | 4.0 | 100 | 3.7 |
| 30J-8.5-100-10 | 8.5 | 100 | 10 | ||
| 30J-4.0-200-5.0 | 4.0 | 200 | 5.0 | ||
| 30J-8.5-200-15 | 8.5 | 200 | 15 | ||
|
Type 31 Flow-Through Sample Cells-. Stainless steel with polypropylene funnel and exit tubing. An excellent cell for high volume applications where sample volumes can be 90ml or more. | 31-8.5-50-5.0 | 8.5 | 50 | 5.0 |
| 31-8.5-100-10 | 8.5 | 100 | 10 | ||
| 31-8.5-200-15 | 8.5 | 200 | 15 | ||
|
Type 31J Jacketed Flow-Through Sample Cells: Type 31 with a stainless steel jacket surrounding the main body of the cell for circulation of temperature control fluids. | 31J-8.5-100-10 | 8.5 | 100 | 10 |
| 31J-8.5-200-15 | 8.5 | 200 | 15 | ||
|
Type 31T Flow-Through Sample Cells: Stainless steel with polypropylene tunnel and exit tubing. This cell has a built-in temperature sensor which automatically measures the sample temperature inside the cell and sends the temperature to the AUTOPOL IV or AUTOPOL 880 for correction to 20'C, 25'C or any customer specified temperature. | 31T-8.5-100-10 | 8.5 | 100 | 10 |
| 31T-8.5-200-15 | 8.5 | 200 | 15 | ||
|
Type 32 Small Volume Sample Cells: Stainless steel with small inlet and outlet ports on both ends of the cell for filling with a pipette. Also available with HPLC fittings. | 32-2.5-10-0.05 | 2.5 | 10 | 0.05 |
| 32-5-25-0.5 | 5 | 25 | 0.5 | ||
| 32-2.5-50-0.25 | 2.5 | 50 | 0.25 | ||
| 32-5-50-1.0 | 5 | 50 | 1.0 | ||
| 32-2.5-100-0.5 | 2.5 | 100 | 0.5 | ||
| 32-5-100-2.0 | 5 | 100 | 2.0 | ||
|
Type 32J Small Volume Jacketed Sample Cells: Type 32 with stainless steel jacket surrounding the main body of the cell for circulation of temperature control fluids. Also available with HPLC fittings. | 32J-5-50-1.0 | 5 | 50 | 1.0 |
| 32J-2.5-100-0.5 | 2.5 | 100 | 0.5 | ||
| 32J-5-100-2.0 | 5 | 100 | 2.0 | ||
|
Type 40T TempTrol™ Sample Cells: Type 40T with stainless steel sample area surrounded by Delrin for thermal insulation is designed for use with the AUTOPOL V Polarimeter TempTrol™ Electronic Temperature Control System. | 40T-2.5-100-0.5 | 2.5 | 100 | 0.5 |