Homepage Polarimeters

Rudolph Research Analyical - Polarimeter Sample Cells

Comprehensive Range of Polarimeter Sample Cell Assemblies Rudolph Polarimeter Cells offer significant advantages over traditional fused end all glass cell designs. All glass cells are easily broken, often build up optically active residue on the inside of the glass ends and require the user to change the instrument's aperture whenever the cell is changed.

Rudolph Polarimeter Cells eliminate these problems by using stainless steel ends with built-in apertures which may be removed to allow the glass to be cleaned if necessary. Cells are manufactured using Pyrex glass and stainless steel for their high resistance to solvents, low temperature coefficient of expansion and general dimensional stability.

Easy Cleaning

Polarimeter Sample Cell Assembly Screw caps, washers, and end plates are easily removed for cleaning the glass or silica ends, sample cell interiors, or for replacement of the washers and end plates. To reassemble the cell requires following the configuration to the left and then applying finger tight pressure to the screw caps. As the screw caps are turned, the washers are compressed against the end plates creating a leak proof seal with the precision ground cell ends. Minimal screw cap pressure and the compressibility of the washer ensures a tight seal without causing stress induced birefringence in the glass end plates. The screw caps have precision apertures which reduce the beam diameter to less than the internal diameter of the cell so that, when the cells are aligned with the beam, internal sidewall reflections and consequent depolarizing effects are minimized. Flanges on the cells align them coaxially within the 30mm diameter chamber rails which are standard in all Rudolph Polarimeters and saccharimeters.

Easy Filling

Sample solutions are either poured or pipetted into the center well, side well or side tubulation. Air bubbles are released by tilting cells side to side or to one side while filling. Flexible tipped pipettes capable of reaching from the center well to either end of the sample can be helpful in filling narrow bore cells.

AUTOPOLs Accept Sample Cells from 10mm to 200mm Long

Some polarimeters accept only special sample cells, with maximum lengths of 100mm. AUTOPOL Polarimeters and saccharimeters accept cells up to 200mm long. A 200mm sample cell offers twice the sensitivity as the same solution in a 100mm cell. This additional optical path length is especially useful for solutions having small rotations. For precious samples and essential oils with large optical rotations, cells with only 0.02ml volumes and 10mm optical path lengths are available.

Rapid Operation

Flow Through Polarimeter Sample Cell Diagram Rapid Operation is achieved by using a flow through polarimeter sample cell as seen to the right. Once the polarimeter sample cell is filled, each successive sample poured into the funnel will displace the previous sample through the drain tube. This method eliminates opening and closing the sample chamber door and interchanging sample cells. Measurements can be made about as rapidly as successive samples can be poured.

Continuous Sampling Capability

Flow Through Polarimeter Sample Cell Diagram Gasketing in the top of the sample trough allows connection to a process stream. Readings can be downloaded via the RS232 port to a computer at fixed intervals, or when prompted by an operator or computer. Custom cells with special ferrels and fittings are available to allow connection to process streams.


Temperature Control

Flow Through Polarimeter Sample Cell Diagram All Rudolph Research Analytical jacketed cells are available with quick release fittings which allow cells to be easily removed from the sample chamber. Tubing is held in place by rubber gasketing on top of the trough and the door. Temperature control is obtained through the use of an external water bath and a jacketed cell.

Autopol V Polarimeter Sample Compartment The AUTOPOL V Polarimeter uses the TempTrol™ Electronic Heating and Cooling System and TempTrol™ sample cells to eliminate the need for a circulating bath. Simply fill your TempTrol™ sample cell, set the temperature control set point of the AUTOPOL V and press "measure". The TempTrol™ System will heat or cool your sample to the set temperature and make the measurement.


Glass Stopper Cells

Glass Stopper Cell For highly evaporative or noxious samples, all Rudolph glass polarimeter cells are available with glass stoppers. Both the stopper and the inside of the glass are ground for an air tight fit.

Micro Volumes

Micro Volume Cell If your application demands 1ml or less, Type 32 Cells offer less than 0.5ml volumes and can be ordered with HPLC fittings transforming your polarimeter into an optical activity detector.


Selection

With over forty-five cells to choose from, Rudolph Research Analytical has a cell to meet every application. Please call our offices for assistance in selecting the best polarimeter sample cell for your application.

Sample Cell Specifications

Type Description Catalog
Number
ID
(mm)
Sample
Length
(±0.002mm)
Sample
Volume
Type 2 Cell Type2 Polarimeter Sample Cells: Straight Pyrex glass cells with metal collars and screw ends. 2-1.6-10-.02 1.6 10 .02
2-4.0-10-.13 4.0 10 .13
2-1.6-50-0.1 1.6 50 0.1
2-1.6-100-0.2 1.6 100 0.2
2-4.0-100-1.3 4.0 100 1.3
2-8.5-100-5.7 8.5 100 5.7
2-4.0-200-2.5 4.0 200 2.5
2-8.5-200-12 8.5 200 12
Type 6 Cell Type 6 Polarimeter Sample Cells: Pyrex glass with one enlarged end to trap air bubbles above the optical path. 6-8.5-100-10 8.5 100 10
6-8.5-200-15 8.5 200 15
Type 14 Cell Type 14 Polarimeter Sample Cells: Pyrex glass with center well for easy filling via pour-in method or with a flexible tipped pipette. 14-4.0-100-1.5 4.0 100 1.5
14-8.5-100-6.0 8.5 100 6.0
14-4.0-200-2.8 4.0 200 2.8
14-8.5-200-12 8.5 200 12
Type 14J Cell Type 14J Jacketed Polarimeter Sample Cells: Pyrex glass with center well. The main body of the cell is completely surrounded by a stainless steel jacket with tubulations at each end for circulation of temperature control fluids. 14J-4.0-100-1.5 4.0 100 1.5
14J-8.5-100-6.0 8.5 100 6.0
14J-4.0-200-2.8 4.0 200 2.8
14J-8.5-200-12 8.5 200 12
Type 29 Cell Type 29 Flow-Through Sample Cells: Stainless steel with tubulations at each end for circulation of sample liquids. Designed so that sample flow washes interior windows eliminating dead volume in the optical path. 29-8.5-100-10 8.5 100 10
29-8.5-200-15 8.5 200 15
Type 29J Cell Type 29J Flow-Through Jacketed Sample Cells: Type 29 but with a stainless steel jacket surrounding the main body of the cell for circulation of temperature control fluids 29J-8.5-100-10 8.5 100 10
29J-8.5-200-15 8.5 200 15
Type 30 Cell Type 30 Polarimeter Sample Cells: Stainless steel with a well at either end for easy filling. 30-8.5-50-5.0 8.5 50 5.0
30-4.0-100-3.7 4.0 100 3.7
30-8.5-100-10 8.5 100 10
30-4.0-200-5.0 4.0 200 5.0
30-8.5-200-15 8.5 200 15
Type 30J Cell Type 30J Jacketed Sample Cells: Type 30 with stainless steel jacket surrounding the main body of the cell for circulation of temperature control fluids. 30J-4.0-100-3.7 4.0 100 3.7
30J-8.5-100-10 8.5 100 10
30J-4.0-200-5.0 4.0 200 5.0
30J-8.5-200-15 8.5 200 15
Type 31 Cell Type 31 Flow-Through Sample Cells-. Stainless steel with polypropylene funnel and exit tubing. An excellent cell for high volume applications where sample volumes can be 90ml or more. 31-8.5-50-5.0 8.5 50 5.0
31-8.5-100-10 8.5 100 10
31-8.5-200-15 8.5 200 15
Type 31J Cell Type 31J Jacketed Flow-Through Sample Cells: Type 31 with a stainless steel jacket surrounding the main body of the cell for circulation of temperature control fluids. 31J-8.5-100-10 8.5 100 10
31J-8.5-200-15 8.5 200 15
Type 31T Cell Type 31T Flow-Through Sample Cells: Stainless steel with polypropylene tunnel and exit tubing. This cell has a built-in temperature sensor which automatically measures the sample temperature inside the cell and sends the temperature to the AUTOPOL IV or AUTOPOL 880 for correction to 20'C, 25'C or any customer specified temperature. 31T-8.5-100-10 8.5 100 10
31T-8.5-200-15 8.5 200 15
Type 32 Cell Type 32 Small Volume Sample Cells: Stainless steel with small inlet and outlet ports on both ends of the cell for filling with a pipette. Also available with HPLC fittings. 32-2.5-10-0.05 2.5 10 0.05
32-5-25-0.5 5 25 0.5
32-2.5-50-0.25 2.5 50 0.25
32-5-50-1.0 5 50 1.0
32-2.5-100-0.5 2.5 100 0.5
32-5-100-2.0 5 100 2.0
Type 32J Cell Type 32J Small Volume Jacketed Sample Cells: Type 32 with stainless steel jacket surrounding the main body of the cell for circulation of temperature control fluids. Also available with HPLC fittings. 32J-5-50-1.0 5 50 1.0
32J-2.5-100-0.5 2.5 100 0.5
32J-5-100-2.0 5 100 2.0
Type 40T Cell Type 40T TempTrol™ Sample Cells: Type 40T with stainless steel sample area surrounded by Delrin for thermal insulation is designed for use with the AUTOPOL V Polarimeter TempTrol™ Electronic Temperature Control System. 40T-2.5-100-0.5 2.5 100 0.5

Return to Top of Page

Return to HomePage