MAIN FEATURES and BENEFITS
Philips Tungsten-Halogen source lamp
Hamamatsu Photodiode Detector
1200 lines/mm grating monochromator
Wavelength range 325 to 1000nm
Narrow 5nm bandpass
Automatic stray light filter selection
Stores up to 200 methods/results
Concentration calibration:
up to 8 standards
up to 3 replicates
linear or linear through zero
Auto-zero by push-button
Stable, noise-free readings
Read-out in Abs, %T, Conc or Factor
RS232 output for printer or PC
PC consumables option
Large sample compartment (155 x 70 x 85mm)
Comprehensive range of sampling accessories:
4 position manual cell changer (10mm pathlength)
4 position long pathlength cell changer (10 - 50mm)
Test tube holder (10 to 25mm diameter tubes)
Thermostatted cell holder (requires water bath)
Using a reconfigured grating monochromator from the successful M105 and M106 models, the M107 offers more performance and versatility with only a modest price difference. The large sample compartment allows the use of a wide range of accessories, including a 4-position cell changer with holder for cell pathlengths up to 50mm. A membrane keyboard positioned next to the large clear LCD display allows the operator to rapidly switch between the %Transmission, Absorbance and Concentration modes and to set Zero.
Signal processing and results display are microprocessor controlled and the narrow 5nm bandpass gives improved analytical sensitivity. The outstanding optical performance is also indicated by the low zero drift (less than 0.001 Abs/Hour) and the low stray light (0.1%T @ 340nm). The fundamental reliability of the instrument is also assured by the absence of motor drives - wavelength selection is by rotary control. This simple mechanism automatically selects the order sorting filters, offers permanent wavelength calibration and eliminates wavelength initialisation routines at switch-on.
The RS232 output provides a convenient link to a PC or serial printer for hardcopy. A low-cost application program which runs under WindowsTM includes the facility to create calibration curves. The reaction kinetics program, when used with the thermostatted cell holder accessory, provides an excellent low-cost enzyme analysis system.
| Wavelength Range | 325 to 1000nm | Photometric accuracy | +/- 1%A, 0-2A |
| Optics | Single beam | Light Source | Tungsten-Halogen lamp |
| Monochromator | 1200 lines/mm | Detector | Photodiode |
| Bandpass | 5nm | Data output | RS232 for printer or PC |
| Wavelength accuracy | +/- 2nm | Noise | Less than 0.001A @ 0.000A |
| Wavelength repeatability | +/- 1nm | Zero drift | Less than 0.001A/hr |
| Stray light | Less than 0.1%T @ 340nm | Weight | 7Kg |
| Photometric ranges |
-1 to 2.5A, 0-125%T, -9999 to +9999C |
Dimensions (W,D,H) | 408 x 320 x 165mm |